Victron Energy 12/24V-400A Intelligent Battery Channel Combiner CYR010400000

CYRIX-I 12/24V-400A
Victron Energy 12/24V-400A Intelligent Battery Channel Combiner CYR010400000

$409 inc GST.

Our Best Price

Qty:     

Shipping & Handling Calculator:

Post Code:
Model No CYRIX-I 12/24V-400A
Selling Unit EACH
Description Victron Energy 12/24V-400A Intelligent Battery Channel Combiner CYR010400000
Original Brand Victron Energy CYR010400000d
Voltage 12/24V
Brand Victron Energy
Size 400A
Width 102mm
Height 78mm
Length/Breadth/Depth 110mm
Weight 900g
Weight(kg) 1
Brand Victron Energy
The Cyrix Battery Combiner is a microprocessor controlled heavy duty relay that automatically connects batteries in parallel when one of them has reached a pre-set voltage (indicating that the battery is being charged), and disconnects when the voltage decreases below float level (indicating that one or more batteries are being discharged). Cyrix Battery Combiners are an excellent replacement for diode isolators. The main feature is that there is virtually no voltage loss so that the output voltage of alternators or battery chargers does not need to be increased.

New: intelligent battery monitoring to prevent unwanted switching
Some battery combiners will disconnect a battery in case of a short but high amperage load. A battery combiner also may fail to connect a large but discharged battery bank because the DC voltage immediately drops below the disengage value once the batteries are connected.
The software of the Cyrix-i does more than simply connect and disconnect based on battery voltage and with a fixed time delay. The Cyrix-i looks at the general trend (voltage increasing or decreasing) and reverses a previous action only if the trend has reversed during a certain period of time. The time delay depends on the voltage deviation from the trend.
In addition, four switch timing profiles can be chosen (see back page).

12/24 V and 24/48 V auto ranging
The Cyrix-i automatically detects system voltage.

No voltage loss

Cyrix battery combiners are an excellent replacement for diode isolators. The main feature is that there is virtually no voltage loss so that the output voltage of alternators or battery chargers does not need to be increased.

Prioritizing the starter battery
In a typical setup the alternator is directly connected to the starter battery. The accessory battery, and possibly also a bow thruster and other batteries are each connected to the starter battery with Cyrix battery combiners.
When a Cyrix senses that the starter battery has reached the connect voltage it will engage, to allow for parallel charging of the other batteries.

Bidirectional voltage sensing and power supply from both batteries
The Cyrix senses the voltage of both connected batteries. It will therefore also engage if for example the accessory battery is being charged by a battery charger.
The Cyrix-i has a dual power supply. It will therefore also close if the voltage on one battery is too low to operate the Cyrix.
In order to prevent unexpected operation during installation or when one battery has been disconnected, the Cyrix-i will not close if the voltage on one of the two battery connections is lower than 2 V (12 V battery), or 4 V (24 V battery) or 8 V (48 V battery).

Parallel connection in case of emergency
The Cyrix can also be engaged with a push button (Cyrix remains engaged during 30 s) or a switch to connect batteries in parallel manually.
This is especially useful in case of emergency when the starter battery is discharged or damaged.